CO2 INCUBATOR
CARBON DI-OXIDE INCUBATOR “MAC” MSW-129
Developed with the introduction of new techniques with highest precision. High is demand in medical research and pharmaceutical industry. Provides sterile and favorable conditions for cultivation are required for cells to grow in germ free environment.
- Selection support
- Configuration guidance for your application
- Delivery
- Pan-India coordination from Mohali
- After-sales
- Installation, calibration and maintenance support
Product details
Features and construction
Description
- “MAC” CO₂ incubator adopts 6-sided direct heat control with temperature uniformity up to ±0.3°C. 140°C dry heat autoclaving function can achieve complete sterilization infrared (IR) CO₂ concentration detector for precise control touch control panel can easily view historical data curves and export historical data with one click. Builtin HEPA air filtration system, which provides continuous protection against harmful airborne contaminants in the culture environment.
Features
- 6-side direct heat system temperature uniformity ±0.3°C.
- 140°Chigh temperature dry heat sterilization
- ISO Class 5 HEPA filtered airflow system.
- Circulating airflow technology ensures uniformity of temperature and humidity
- 304 Stainless Steel cavity with rounded corners, beautiful and easy to clean
- Removable shelf holder, no additional tools required
- 5-inch LCD touch operation screen, simple and intuitive to operate, data exportable
OPTIONS
- CO₂ Regulator double stage.
- Carbon Dioxide gas cylinder of 10 Ltrs. Water Capacity
Technical data
Specifications and models
| Model | Capacity |
|---|---|
| #CDI-80 (PRO) | 80 Ltrs. |
| #CDI-150 (PRO) | 150 Ltrs. |
Control Interface
5 inch LCD touch operation screen
Temperature Control Mode
PID control mode
Temperature Control Range
Ambient +5°C ~ 60°C
Temperature Display Resolution
0.1°C
Temperature Field Uniformity
±0.3°C at 37°C
Max. Power
900W
Timing Function
0~999.9hours
CO₂ Measurement Principle
Infrared (IR) detection
CO₂ Control Range
0~20%
CO₂ Display Resolution
0.1%
CO₂ Supply
0.05~0.1MPa is recommended
Relative Humidity
Ambient humidity ~95% at 37°C
HEPA Filtration
ISO 5 level, 5 minutes
Sterilization Method
140°C High heat sterilization
Temperature Recovery Time
≤ 10 min (open door 30 sec room temperature 25°C set value 37°C)
CO₂ Concentration Recovery Time
≤ 5 min (open the door 30 sec set value 5%)
Historical Data Storage
250,000 messages
Data Export Interface
USB interface
User Management
3 levels of user management : Administrator/Tester/Operator
Working Environment Temperature
10~30°C
Power Supply
115V~230V±10%, 50~60Hz